Your Trusted Source for Industrial Electrical Components
Industry Applications

Current Sensing in Industrial Motor Drives: How LEM Transducers Are Used

Learn how current sensors support VFD and servo-drive control, from motor-phase feedback to isolation, bandwidth and mounting choices.

SafeCirk Editorial  ·  May 11, 2025  ·  LEM  ·  4 min read

An industrial motor drive changes the voltage and frequency applied to a motor to manage torque, speed and position. Whether the machine is a conveyor, lift, robot, pump or servo axis, feedback about electrical current is central to control and protection. A well-specified current transducer helps the drive controller understand what the inverter and motor are actually doing.

LEM lists industrial drives among its current-sensor applications, including robots, elevators and machine tools. The aim here is to explain measurement positions and purchasing criteria—not to claim that any one LEM model fits every drive.

Typical measurement points

Motor phases. Two or three phase-current measurements are common in closed-loop motor control. The controller uses phase information in current regulation, torque-producing current estimation and fault detection. The sensing arrangement depends on the inverter topology and the control algorithm. Two sensors can be sufficient for some three-phase systems, but that is not a universal rule.

DC link. A sensor may monitor current entering or circulating in the DC link. This can support supervision and diagnostics, but a DC-link reading does not automatically replace phase measurements for a high-performance control loop.

Supply or auxiliary branches. Drives may also measure input or brake-related currents. Each location has a different waveform and transient profile, so the same nominal amperage does not guarantee equivalent suitability.

What the controller needs from a sensor

For fast feedback, engineers evaluate bandwidth, group delay and dynamic response along with static accuracy. PWM switching introduces rapidly changing voltages and common-mode disturbances. The transducer must tolerate the electrical environment without turning switching noise into misleading feedback.

Resolution and offset matter at low motor torque, while range and overload behavior matter during acceleration, braking, stalled-load events and short transients. Temperature drift can become noticeable in enclosures that run hot for long periods. Review these parameters over the intended operating range rather than quoting one catalog figure.

Isolation and integration

A current transducer can provide galvanic isolation between a high-energy primary conductor and low-voltage control electronics; the exact insulation rating must match the system. PCB-mounted sensors, panel-mounted sensors and busbar-through designs solve different mechanical problems. Wiring length, output loading, grounding, creepage and clearance all deserve review.

When the drive uses multiple sensors, consider matching and calibration between channels. A controller can be sensitive to differences in gain, delay or offset even if each transducer individually meets its datasheet.

LEM families worth reviewing

LEM's industrial-drive application material lists families including CKSR, CASR, LA, HLSR, LKSR and LF, among others. These families span different measurement principles and current ranges. For instance, the CKSR family is presented by LEM as a compact current sensor for drive applications, while other families address different currents, footprints or signal formats.

The point is to build a shortlist by electrical requirements, not choose by a familiar series name. Two models in the same family may differ in rated current or another suffix-dependent feature. Always verify exact part-number documentation, including the output signal and primary connection arrangement.

Example: a servo-axis design review

Suppose a design team is updating a servo drive and wants better repeatability at low speed. Instead of asking only for “a 100 A Hall sensor,” it should document the phase-current waveform, peak motor current, switching frequency, acceptable feedback delay, offset budget, operating temperature and isolation requirements. The team should also check PCB height, pinout and existing ADC input range. These details determine which sensor architectures and variants remain plausible.

No sensor should be promoted as a drop-in replacement before the actual wiring, footprint, accuracy and response characteristics are compared.

Frequent mistakes to avoid

  • Using the current needed for steady-state motor operation as the only sizing input, without reviewing acceleration and fault transients.
  • Selecting an impressive bandwidth figure without checking noise, delay and the controller's practical sampling scheme.
  • Assuming every transducer output is the same voltage or current format.
  • Ignoring EMI, nearby busbars or installation position when troubleshooting strange readings.
  • Treating a shared base model name as proof that two suffix variants are interchangeable.

What to include in an RFQ

Provide the full LEM part number when available, plus phase or DC-link measurement point, current waveform and range, bandwidth/response requirements, supply, output, isolation, mounting and environmental conditions. If replacement is the goal, include the current datasheet and an explanation of why the original part is being changed. This is more useful than requesting a generic “current sensor for inverter.”

Conclusion

Industrial drive current measurement links power electronics to the control algorithm. The right transducer must meet the current profile, control bandwidth, noise environment and physical layout simultaneously. LEM's motor-drive portfolio offers multiple options, but the exact variant needs technical verification before design-in or purchase.

Manufacturer references